

xgenus and xgenus DC are the latest evolution of the worldwide known de Götzen intraoral generators, designed for the highest level of reliability to keep the user interaction experience at the same level over time, enclosing the finest technology to guarantee high standards of image quality and beautifully designed for a perfect integration in any environment.
genus® dc is functionally simple in design but at the same time is extremely sophisticated in features and benefits providing a single-phase and a high frequency system in one. A system which sets a new standard in quality and safety.
It has been engineered to work at high frequency mode. - its simple, intuitive anatomical controls assure perfect x-ray radiographic results with any patient and technique. - its simplicity of use provides the radiological operator with complete control and a significant savings of time and money.
Thanks to this new revolutionary engineering, with the de Götzen® open system, it is possible to add a second arm and tube head to the first xgenus® ac/dc system (single phase or high frequency): a unique versatility that increases the operating capacity and provides selection of the proper x-ray technology for the diagnosis required, and, at the same time, reducing the economic investment. de Götzen® xgenus® dc is truly an innovative and unique system: the Next Generation.
Discover the de Götzen® patented open system and you will understand why it is even more than this!
Mani Feature:
it is a high frequency system at constant potential, that allows the output of very good quality radiations during every use condition
xgenus® dc can supply 60/70kV or 4/8mA to optimize the diagnostic value of the intra-oral exposures. It reduces the exposure times of 35% in comparison with the single-phase system
it is properly protected against radiation leakage (according to IEC standard: less than 0,25 mGy/h at 1m, the real value can be considerabily less than 0,1 mGy/at 1 m);
the focus / skin distance of 12-inch (31cm.) (standard) helps to maximize the use of the paralleling technique. - with the short cone (optional) the distance is reduced to 8-inch (20cm.);
the xgenus® timer is a new design suitable to satisfy the most recent hardware and software standards;
it is easy to read and fast to set up. - the huge possibility of choosing the pre-set exposure times can be modified when the operator wants to get values suitable to a more personal use;
it has the possibility to control two x-ray units. This is absolute new as you can connect two xgenus® (ac technology) or two xgenus® dc, namely: one "ac" + one "dc";
the exposure time charts are arranged for films type "D""E""F" and for most part of digital imaging systems;
visual and audible signals indicate that the x-ray exposure has been made;
it has the possibility to connect the red warning light (xgenus® light) outside the x-ray room;
it has the possibility to connect the exposure control button (with safety key) of the timer outside the x-ray room (xgenus® exposure control button);
the automatic self-test assures proper operation of all electronic functions (error codes immediately indicate any faults);
the safety key is an additional way to prevent improper use of the unit when the system is switched off;
it displays the line voltage and collect the operating data during the use;
the pantograph arm assures smooth, accurate and firm control. It can be adjusted for 40cm, 80cm (standard),110cm extender arms as well as for unit, ceiling and mobile;
the installation of the system is easy and very fast;
MECHANICAL DATA
Total weight :19,5 kg (wall mounting)
47 kg (mobile version)
Weight of the tubehead:5,5 Kg
Mechanical configuration: Wall mounting, top and bottom / Mobile
Source-skin distance (SSD): short cone 20 cm (8’’)
long cone 31 cm (12’’)
rectangular cone 31 cm (12’’)
X-ray beam dimension: short cone ≤ 60 mm
long cone ≤ 60 mm
rectangular cone 44x35 mm
RELIABLE TECHNOLOGY
The intraoral generators of the xgenus family pack together the years of experience of degotzen in designing technologically advanced and reliable solution for dental radiology field. The two members of the family, the DC and the AC version, are engineered to guarantee high quality beam and precise control on the exposure times, for the best outcome of any exam.
HIGH FLEXIBILITY
The different options available allows you to configure the device tailored on your needs and your preferences, wide selection of arm lengths is available as well as a full set of cone types which allow you set the shape of the beam and the source-to-skin distance, everything ensuring the best experience as always on device positioning during its operation: the arm is light enough to be positioned with one finger!
CLEAN DESIGN
The clean and simple design of the xgenus family generators guarantees a seamless integration of the devices in any environment. The interaction with the unit is outmost simple thanks to high user-friendliness of the control panel equipped with large soft touch buttons and LED lights to always have under control the status of the device.
Out of Stock